Levabo Turn All Patient Turning Mattress System - 3C

SKU
LV1100

Automatic Lateral Turning System supports clinicians and carers in the regular turning of primary immobile patients, who are at the risk of developing pressure ulcers and for those who have existing pressure ulcers.

Easy to set up and use.

Turning cycle at regular intervals of 30, 60 or 90 minutes (30/30, 60/60, 90/90 minutes)

Time setting to select the length of time that the automated lateral turning is required.

CPR function for rapid deflation.

 

Download the Care England white paper about the Turn-All:
Preventing Pressure Ulcers: The Role of Automatic Lateral turning Systems for Innovative Approaches to Pressure Ulcer Prevention in Care Homes

Sold: Full System

Incl. VAT Exl. VAT
£1,628.59 £1,357.16
Levabo
GB https://schema.org/MerchantReturnFiniteReturnWindow 14 https://schema.org/ReturnByMail https://schema.org/FreeReturn
GB
5.95 18 GBP
0 1 DAY
1 3 DAY

2 Day Delivery. FREE over £75
Supplier to the NHS
PayPal | Apple Pay | Google Pay
Same Day Despatch - Before 2.30pm
Buy | Try | Review = 20% OFF Next Order
ISO 13485 Supplier for Medical Devices
Product Description

Levabo Turn All Patient Turning Mattress

Patient Turning Device for pressure redistribution. The Turn All System turns a  hospital-style medical profiling bed into an automated lateral positioning bed by placing the system under the existing mattress.

Suitable on beds with a rising backrest.

Turning cycles: 30 / 60 / 90 minutes Positioning: 0–30° + 5° counter wedge Max user weight: 225 kg Cover washable: up to 90°C



WARNING: This product is intended for use on hospital-style healthcare/profiling beds only with a removable mattress. Domestic beds and non-medical bed frames are not suitable.

IMPORTANT: The user manual must be fully read before installation, operation, cleaning, or troubleshooting. Incorrect installation or improper use can cause patient harm and/or product damage.

Overview

Developed by Levabo in Denmark, this Automatic Lateral Turning System (ALTS) supports clinicians and carers in the regular turning of primary immobile patients who are at risk of developing pressure ulcers, and for those who have existing pressure ulcers in acute or community settings.

Gentle, quiet turning Reduced manual handling Side support to reduce shear CPR rapid deflation

Easy to use

  • Easy to set up and use.
  • Turning cycle at regular intervals of 30, 60 or 90 minutes (30/30, 60/60, 90/90).
  • Time setting to select how long automated lateral turning is required.
  • CPR function for rapid deflation.
Fits on any suitable bed: Intended for healthcare/profiling beds with removable mattresses. Can be used with air flow, hybrid, foam, and some dynamic mattresses.

Indications

For primary immobile patients who are at risk of developing pressure ulcers and those with existing pressure ulcers requiring frequent repositioning.

  • Prevention of pressure injuries / ulcers
  • Treatment of existing injuries / ulcers
  • Paraplegia / spinal cord injuries
  • Neurological conditions
  • Dementia, complex needs
  • Immobile or limited mobility
  • End of life / palliative care

Contraindications / risks of use

The product cannot be used in patients with:

  • Mobile patients who turn themselves in bed
  • Unstable fractures
  • Severe burn injuries
  • Equilibrium disorders
  • Underlying neurological diseases leading to anxiety behaviour in patients
Care responsibility: Even with Turn All® in use, skin should be assessed regularly by caregivers and/or qualified medical personnel.

Features & benefits

  • Comprehensive pressure relief.
  • Lateral turning positioning system: 0–30° with patented 5° counter wedge.
  • Comfortable and doesn’t interrupt normal sleep.
  • Automatically turns the user gently and quietly.
  • Gentle positioning even for patients in pain.
  • Improved body temperature and blood circulation.
  • Provides consistent “head to toe” support.
  • Side support system reduces the feeling of sliding away from the primary lift side and helps reduce shear risk.
  • Patients can be carefully and easily turned, supporting staff health and wellbeing.
  • Manual handling requirements are reduced.
  • Time saving results in more care time available for the patient.
  • Robust, durable and reliable.
  • Can be integrated into any suitable care bed with a removable mattress.
  • Can be washed at 90°C.

What’s included

  • Turn All Pump System
  • Power cord to the pump system
  • Turn All lift mattress
  • Turn All cover (lift mattress supplied pre-assembled inside the cover)
  • User manual

Specifications

Dimensions 200 cm × 85 cm
Max weight bearing 225 kg
Max air pressure (pump) 60 mmHg
Materials Air system: Nylon TPU
Upper cover: BI Elastic PU
Lower cover: 600D TPU Coating Dacron Fabric
Compatibility Healthcare / hospital-style profiling beds with removable mattress; suitable on beds with rising backrest

Clinical efficiency

Clinical practice guidelines recommend regular repositioning for patients with reduced mobility. Repositioning reduces prolonged pressure on vulnerable areas, helping reduce the risk of further skin breakdown.

  • NICE CG179 (2014) includes repositioning within prevention and management strategies for pressure ulcers.
  • International pressure ulcer guidelines (EPUAP, NPIAP and PPPIA) recommend the 30° lateral side-lying position.
  • Repositioning can relieve tissue compression and restore blood flow (Moore ZE, Cowman S. Cochrane review).

Compliance

  • Active medical product in accordance with EU MDR (EU) 2017/745, Medical Devices – Class I
  • EN ISO 9001:2015 QMC
  • EN ISO 13485:2016 MD-QMC

Quick guide videos

 

Quickguide 1: Installation (EN)

Installation quick guide (English).

Turn All® system overview

How the system supports automated lateral positioning.

Disclaimer: Turn All is an aid to prevention and an adjunct therapy for treatment of pressure injuries. Claims for damages resulting from improper or inappropriate use are excluded; the operator is responsible for damages in the event of incorrect or inappropriate use.

 

 

Patient Turning Mattress

Turn All FAQ

What is the Turn All Mattress System?

The Turn All Mattress is a specialised pressure-relief mattress designed for use in care homes. It features advanced technology to reduce the risk of pressure ulcers and to enhance patient comfort.

How does the Turn All Mattress help prevent pressure ulcers?

This mattress uses a combination of alternating pressure and continuous low pressure to evenly distribute weight and reduce pressure points, which are critical in preventing pressure ulcers.

Is the mattress suitable for all patients?

Yes, the Turn All System 3CT Mattress is designed to accommodate a wide range of patients, including those at high risk of pressure ulcers. It is particularly beneficial for immobile or bedridden individuals.

How easy is it to maintain the mattress?

The mattress is designed for easy maintenance with a durable cover that is easy to clean and disinfect. It also features a modular design, allowing for quick and easy repairs or replacements of parts.

Can the mattress be used with existing bed frames?

Yes, the Turn All is compatible with medical profiling beds with a removable mattress, turning it into an automatic lateral positioning bed. 

What are the benefits of using this mattress in a care home setting?

The mattress helps reduce the incidence of pressure ulcers, improves patient comfort, and reduces the need for frequent repositioning, which can ease the workload for care home staff.

How does the mattress adjust to different patient needs?

The Turn All System adjusts to different patient needs by automatically repositioning them into a 30-degree lateral position at set intervals (30,60,90 mins), reducing pressure and enhancing comfort.

Is the Turn All Mattress energy efficient?

Yes, the mattress is designed to be energy efficient, minimising power consumption while still providing effective pressure relief.

How long does the mattress last?

The Turn All Mattress is built to be durable and long-lasting, providing reliable service for several years with proper maintenance.

We found other products you might like!