Enigma Autoclave Steriliser - Class B - 8 Litre
Compact and efficient vacuum steam autoclave steriliser ideal for clinics. Very simple to operate.
Sold: Each
Incl. VAT Exl. VATProduct Description
Class B Autoclave Steriliser
Compact professional steam sterilisation for smaller clinics and practices.
The Enigma 8 Litre Class B Autoclave is a vacuum steam steriliser designed for the reprocessing of suitable reusable clinical instruments. Its compact size makes it particularly practical for podiatry clinics and other professional treatment settings where reliable instrument sterilisation is essential.
Using a Class B vacuum-assisted sterilisation process, the autoclave is suitable for compatible solid, hollow, porous and wrapped loads. It offers two fast cycle options, an 8-litre chamber and straightforward operation, helping practices manage instrument reprocessing within a limited clinical workspace.
Supplied with two instrument trays and supported by a one-year warranty, it provides a practical sterilisation solution for clinics that do not require a larger-capacity autoclave.
Key Selling Points
Versatile Class B Sterilisation
Designed for a range of compatible instrument loads, including wrapped instruments and suitable hollow or porous items. This makes it useful for clinics processing different types of reusable equipment.
Compact 8 Litre Capacity
Provides professional steam sterilisation without the larger footprint of a high-capacity machine. Particularly suited to smaller practices and clinics with modest instrument loads.
Two Fast Cycle Options
Two sterilisation programmes provide flexibility for compatible loads. Cycle selection should always follow instrument instructions and validated reprocessing procedures.
Practical Day-to-Day Operation
Vacuum-assisted operation, clean-water use and two supplied instrument trays support an organised clinical sterilisation workflow.
Designed for Clinical Environments
A professional instrument steriliser suitable for podiatry and other clinical settings where reusable instruments require controlled steam processing.
Warranty and Servicing Support
Includes a one-year warranty. Installation, servicing, calibration, pressure-vessel inspection and repair services can be arranged separately.
What Does a Class B Autoclave Do?
A Class B autoclave sterilises compatible reusable instruments using high-temperature steam under controlled pressure. Sterilisation is an important stage of instrument decontamination because it is designed to destroy viable microorganisms, including bacterial spores, when the correct validated process is completed.
The Enigma 8L uses a vacuum-assisted process to help remove trapped air before steam sterilisation. Removing air improves steam penetration into difficult-to-reach areas, including suitable hollow instruments and packaged loads.
How the Sterilisation Process Works
- Air removal: The vacuum process helps remove air from the chamber and compatible loads.
- Steam penetration: Steam enters the chamber and reaches the exposed surfaces of correctly prepared instruments.
- Sterilisation: The selected programme maintains the required conditions for its validated sterilisation phase.
- Cycle completion: The load is released only after the required cycle checks and safe unloading conditions have been met.
This process supports instrument reprocessing but does not replace thorough cleaning, inspection, correct packaging or routine steriliser testing.
Common Clinical Sterilisation Challenges It Helps Address
Limited Clinic Space
Smaller treatment rooms may not have sufficient room for larger autoclaves. The 8-litre chamber offers a compact alternative for practices with lower-volume sterilisation requirements.
Different Instrument Types
Clinics may use both solid instruments and equipment containing hollow sections. A Class B process provides greater load flexibility than a basic non-vacuum cycle, subject to instrument compatibility.
Wrapped Instrument Processing
Practices may need to sterilise correctly packaged instruments for subsequent storage and use. Suitable Class B cycles support wrapped loads when the instruments and packaging are compatible.
Instrument Turnaround
Efficient reprocessing is important when instruments are used throughout the working day. Two fast programme options help clinics organise appropriate sterilisation cycles around their clinical workload.
Applications and Suitability
The Enigma 8L Class B Autoclave is designed for professional settings that require the steam sterilisation of compatible reusable instruments.
Typical Professional Users
- Podiatrists and chiropodists: For reprocessing suitable reusable foot-care instruments.
- Medical and treatment clinics: For compatible instruments requiring steam sterilisation.
- Dental settings: For suitable reusable instruments where the chamber capacity and validated cycles meet the practice's requirements.
- Veterinary practices: For compatible clinical tools and instruments.
- Other trained practitioners: Where Class B steam sterilisation is appropriate for the equipment being processed.
Suitable Load Categories
- Compatible solid metal instruments.
- Suitable hollow instruments and devices.
- Correctly packaged reusable instruments.
- Approved steam-compatible porous materials.
Instrument compatibility must be confirmed against the device and instrument instructions before sterilisation.
Who May Need a Different Autoclave?
The 8-litre model may not be the most practical option for every clinical environment.
- High-volume practices: Clinics processing numerous instrument sets may benefit from a 12-litre or 17-litre machine.
- Large instruments: Items exceeding the chamber or tray dimensions cannot be accommodated safely.
- Heat-sensitive equipment: Instruments that cannot tolerate steam, moisture or sterilisation temperatures require an approved alternative method.
- Untrained operators: The machine requires appropriate training, operating procedures, testing and maintenance.
- Sites without suitable facilities: Installation space, electrical requirements and safe operating conditions must be assessed before purchase.
For larger or more frequent instrument loads, compare the available Class B autoclave capacities before choosing.
Product Specifications
| Specification | Details |
|---|---|
| Product | Enigma Class B Autoclave Steriliser |
| Product Code | TG0030 |
| Steriliser Type | Class B vacuum steam autoclave |
| Chamber Capacity | 8 litres |
| Cycle Options | Two fast sterilisation programmes |
| Sterilisation Temperatures | 121–134°C |
| External Dimensions | 350 mm W × 330 mm H × 500 mm D |
| Chamber Dimensions | 170 mm diameter × 320 mm depth |
| Instrument Trays | 2 supplied |
| Tray Dimensions | Approximately 260 × 130 mm |
| Machine Weight | Approximately 37 kg |
| Water Tank Capacity | Approximately 2.5 litres |
| Water Requirement | Distilled water, in accordance with operating instructions |
| Nominal Power | 1550 VA |
| Maximum Power Drawn | 1.5–2 kW |
| Specified Operating Temperature | 5–40°C |
| Mean Sound Level | Less than 70 dB |
| Warranty | 1 year |
| Installation | Not included; available separately using code TG0035 |
| Supply | 1 autoclave steriliser with 2 trays |
Ensure the proposed installation area accommodates the full machine dimensions and any additional operating clearances specified in the installation instructions.
How to Use the Enigma 8L Autoclave
The autoclave should be operated only by personnel trained in safe instrument reprocessing and the machine's operating procedures.
- Prepare the instruments. Clean, rinse, dry and inspect reusable instruments according to the instrument instructions and clinical decontamination procedures.
- Check the autoclave. Confirm the machine is ready for use, the required routine tests have been completed and the water supply meets the operating requirements.
- Prepare the load. Place compatible instruments on the supplied trays or in suitable sterilisation packaging, as required. Do not overload the chamber or obstruct steam circulation.
- Select the correct programme. Choose the sterilisation cycle appropriate to the instrument material, packaging and validated processing requirements.
- Run the sterilisation cycle. Allow the selected programme to complete without interruption and monitor the machine according to the operating instructions.
- Verify completion. Check the cycle results, required indicators and any relevant monitoring records before accepting the load as successfully processed.
- Unload safely. Follow the required cooling, pressure-release and unloading procedures. Handle and store processed instruments according to the practice's infection prevention policy.
Important Operating Guidance
These instructions provide a general overview only. Always follow the complete Enigma 8L operating manual, instrument instructions, approved sterilisation procedures and relevant clinical requirements. Programme selection, routine testing and maintenance must be appropriate to the loads being processed.
Practical Benefits for Your Clinic
More Flexible Instrument Processing
Class B vacuum-assisted sterilisation supports a broad range of compatible load types, helping practices manage different reusable instruments using one machine.
Space-Conscious Equipment Choice
The 8-litre capacity makes it a practical option for clinics where a larger steriliser would be unnecessary or difficult to accommodate.
Supports Clinical Hygiene Procedures
Provides a controlled sterilisation stage within a documented instrument decontamination process, helping support appropriate infection prevention practices.
Convenient Included Accessories
Two instrument trays are provided with the machine, allowing suitable instruments to be positioned for processing in accordance with loading instructions.
Practical Programme Selection
Two fast cycle options allow trained operators to choose an appropriate programme for compatible loads without unnecessary complexity.
Ongoing Equipment Support
A one-year warranty and access to separately arranged maintenance and inspection services provide useful reassurance when planning long-term clinical equipment use.
Contraindications and Important Safety Information
- Professional operation: Use only by appropriately trained personnel familiar with steam sterilisation and pressure equipment.
- Instrument compatibility: Do not process items that are not approved for the selected steam sterilisation conditions.
- Heat-sensitive materials: Some plastics, electronic devices, delicate components and other materials may be damaged by high temperature or moisture.
- Correct cleaning: Instruments must be properly cleaned before sterilisation. The autoclave is not a substitute for instrument cleaning.
- Loading: Do not overload trays, restrict steam circulation or use unsuitable packaging.
- Pressure and heat: Never attempt to open the chamber while a cycle is operating or the machine remains pressurised. Follow safe unloading procedures to avoid steam and contact burns.
- Unsupported loads: Do not process liquids, sealed containers or other specialised loads unless expressly permitted by the equipment instructions and a suitable validated cycle.
- Water quality: Use the specified water type and follow the required cleaning and water management procedures.
- Maintenance: Complete prescribed checks, testing, servicing and applicable pressure-system inspections. Do not continue operating a machine showing faults or failed cycle results.
Correct operation, instrument preparation, cycle monitoring and documentation remain essential to a safe sterilisation process.
Frequently Asked Questions
What is a Class B autoclave?
A Class B autoclave uses a vacuum-assisted steam process to sterilise suitable reusable instruments. The vacuum stage helps remove air so steam can reach difficult areas, including compatible hollow sections and packaged loads. Instruments must still be correctly prepared and processed using the appropriate validated cycle.
Which instruments can the Enigma 8L sterilise?
The machine is designed for compatible solid, hollow, porous and appropriately packaged instrument loads. Each instrument must be approved for steam sterilisation at the selected programme conditions. Single-use instruments or items unsuitable for steam processing should not be placed in the autoclave.
Is an 8-litre autoclave large enough for a podiatry clinic?
An 8-litre chamber can be suitable for smaller practices processing modest instrument loads. Clinics handling larger instrument sets or frequent batches may benefit from a higher-capacity machine. Compare your normal instrument volume, tray requirements and daily workload before choosing.
How many sterilisation cycles does the Enigma 8L have?
The Enigma 8L offers two fast sterilisation programme options, with operating temperatures in the 121–134°C range. The appropriate programme depends on the load and instrument processing requirements. Exact programme settings and timings should always be checked against the operating manual.
What type of water should be used in the autoclave?
Distilled water should be used in accordance with the machine's operating instructions. Correct water quality helps limit mineral deposits and supports appropriate equipment operation. Water levels, quality and maintenance requirements should be checked as part of routine use.
What is included, and does the price include installation?
The Enigma 8L is supplied with two instrument trays. Installation is not included in the standard purchase and can be requested separately using installation code TG0035. We recommend confirming delivery arrangements, installation requirements and any additional charges before ordering.
How can I check that a sterilisation cycle has been successful?
Cycle acceptance should follow your documented testing, monitoring and traceability procedures. Check the cycle completion information and any required process indicators before releasing instruments for use. Failed or interrupted cycles must be managed according to the practice's instrument reprocessing procedures.
What warranty and maintenance support is available?
The Enigma 8L is supplied with a one-year warranty. Servicing, calibration, repairs and pressure-vessel inspections can be arranged separately as required. Regular maintenance and documented routine checks are important for safe ongoing use.
Can heat-sensitive items be sterilised in this machine?
Steam sterilisation involves high temperature and moisture, making it unsuitable for materials that cannot tolerate these conditions. Always check the item's reprocessing instructions before placing it in the chamber. Equipment that is not steam-compatible requires a suitable alternative reprocessing method.
Related Products and Support
Explore alternative chamber capacities, sterilisation accessories and equipment support services.
- Browse Autoclaves and Sterilisation Accessories
- Autoclave Sterilisation Pouches for Podiatry Instruments
- Enigma Class B Autoclave – 12 Litre
- Enigma Class B Autoclave – 17 Litre
- Equipment Servicing, Repairs and Maintenance
- Contact Our Team for Product and Installation Enquiries
Installation and Delivery Information
Installation is charged separately. To request installation, add code TG0035 to your order or contact our team for assistance.
Availability and dispatch times can vary because stock may be held by the equipment supplier. If your order is urgent or installation is time-sensitive, please contact us before purchasing so we can confirm current availability and expected delivery arrangements.
Product Summary
The Enigma 8 Litre Class B Autoclave Steriliser (TG0030) is a compact professional vacuum steam steriliser for compatible reusable clinical instruments. Designed for smaller podiatry and healthcare practices, it offers an 8-litre chamber, two fast sterilisation programmes operating within a 121–134°C temperature range, and two supplied instrument trays. Class B vacuum processing supports suitable solid, hollow, porous and wrapped loads. The machine measures 350 mm wide, 330 mm high and 500 mm deep, includes a one-year warranty and has optional installation and servicing available separately. Correct instrument preparation, operator training, cycle monitoring and regular maintenance are required.










Sold: Each
Incl. VAT Exl. VAT